meritve (57 od skupno 1352 raziskav)
"The exposure levels of ELF-MFs detected in this study could affect children’s perception [27] and is associated
with a higher risk of childhood leukemia [13,14,15,16]. Disorders of cognitive function [17,18,19], disorders of
memory performance, headaches, and sleep disorders [20,21] are also associated with these exposure levels.
Although there has been no explicit evidence for adverse health effects in children by ELF-MFs exposure, since the nervous and immune systems of children could be more sensitive to ELF-MFs [2,28], children should avoid exposure to ELF-MFs as much as possible. Therefore, a reduction policy should be established to minimize exposure levels for children."
"However, for exposures at higher GHz frequencies (millimeter waves and 5G), RF energy absorption tends to be more superficial and concentrated. Energy deposition could quickly occur in a smaller tissue area or mass to cause intense temperature elevation within a very short-exposure time period."
"Expecting that the SARs for cell phones may exceed the safety limits for body contact, cell phone manufacturers have started to recommend that the devices can be used at 5-25 mm from the body even though it is difficult to see how to maintain this distance correctly under mobile conditions. The National Agency ANFR of France recently released the cell phone SAR test data for 450 cell phones that measure 10-g SARs reducing by 10%-30% for each millimeter distal placement from the planar body phantom. Their data corroborate our findings that most cell phones will exceed the safety guidelines when held against the body by factors of 1.6-3.7 times for the European/ICNIRP standard or by factors as high as 11 if 1-g SAR values were to be measured as required by the U.S. FCC."
"The total mean level was 5,494 µW/m2 (median 3,346; range 36.6-205,155). The major contributions were down links from LTE 800 (4G), GSM + UMTS 900 (3G), GSM 1800 (2G), UMTS 2100 (3G) and LTE 2600 (4G). Regarding different places, the highest RF radiation was measured at the Hay Market with a mean level of 10,728 µW/m2 (median 8,578; range 335-68,815). This is a square used for shopping, and both retailers and visitors may spend considerable time at this place. Also, the Sergel Plaza had high radiation with a mean of 7,768 µW/m2. All measurements exceeded the target level of 30-60 µW/m2 based on non-thermal (no heating) effects, according to the BioInitiative Report. Based on short-term thermal effects, The International Commission on Non-Ionizing Radiation Protection established guideline 2 of 10 W/m2 (2,000,000-10,000,000 µW/m2) depending on frequency in 1998, and has not changed it despite solid evidence of non-thermal biological effects at substantially lower exposure levels. These environmental RF radiation levels are expected to increase with the introduction of 5G for wireless communication."
"Children's brains are more susceptible to hazardous exposures, and are thought to absorb higher doses of radiation from cell phones in some regions of the brain. Globally the numbers and applications of wireless devices are increasing rapidly, but since 1997 safety testing has relied on a large, homogenous, adult male head phantom to simulate exposures; the "Standard Anthropomorphic Mannequin" (SAM) is used to estimate only whether tissue temperature will be increased by more than 1 Celsius degree in the periphery. The present work employs anatomically based modeling currently used to set standards for surgical and medical devices, that incorporates heterogeneous characteristics of age and anatomy. Modeling of a cell phone held to the ear, or of virtual reality devices in front of the eyes, reveals that young eyes and brains absorb substantially higher local radiation doses than adults'. Age-specific simulations indicate the need to apply refined methods for regulatory compliance testing; and for public education regarding manufacturers' advice to keep phones off the body, and prudent use to limit exposures, particularly to protect the young."
"Extreme broadband wireless devices operating above 10 GHz may transmit data in bursts of a few milliseconds to seconds. Even though the time- and area-averaged power density values remain within the acceptable safety limits for continuous exposure, these bursts may lead to short temperature spikes in the skin of exposed people. In this paper, a novel analytical approach to pulsed heating is developed and applied to assess the peak-to-average temperature ratio as a function of the pulse fraction α (relative to the averaging time [INCREMENT]T; it corresponds to the inverse of the peak-to-average ratio). This has been analyzed for two different perfusion-related thermal time constants (τ1 = 100 s and 500 s) corresponding to plane-wave and localized exposures. To allow for peak temperatures that considerably exceed the 1 K increase, the CEM43 tissue damage model, with an experimental-data-based damage threshold for human skin of 600 min, is used to allow large temperature oscillations that remain below the level at which tissue damage occurs. To stay consistent with the current safety guidelines, safety factors of 10 for occupational exposure and 50 for the general public were applied. The model assumptions and limitations (e.g., employed thermal and tissue damage models, homogeneous skin, consideration of localized exposure by a modified time constant) are discussed in detail. The results demonstrate that the maximum averaging time, based on the assumption of a thermal time constant of 100 s, is 240 s if the maximum local temperature increase for continuous-wave exposure is limited to 1 K and α ≥ 0.1. For a very low peak-to-average ratio of 100 (α ≥ 0.01), it decreases to only 30 s. The results also show that the peak-to-average ratio of 1,000 tolerated by the International Council on Non-Ionizing Radiation Protection guidelines may lead to permanent tissue damage after even short exposures, highlighting the importance of revisiting existing exposure guidelines."
"The largest contributors to total personal environmental RF-EMF exposure were downlink and broadcast, and these exposures showed high repeatability. Urbanicity was the most important determinant of total exposure and mobile phone use was the most important determinant of uplink exposure. It is important to continue evaluating RF-EMF exposure in children as device use habits, exposure levels, and main contributing sources may change."
"Exposure to radiofrequency (RF) radiation was classified in 2011 as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer of the World Health Organisation. Evidence of the risk of cancer risk has since strengthened. Exposure is changing due to the rapid development of technology resulting in increased ambient radiation. RF radiation of sufficient intensity heats tissues, but the energy is insufficient to cause ionization, hence it is called non-ionizing radiation. These non-thermal exposure levels have resulted in biological effects in humans, animals and cells, including an increased cancer risk. In the present study, the levels of RF radiation were measured in an apartment close to two groups of mobile phone base stations on the roof."
"Mean total RF-EMF exposure in various outdoor microenvironments varied between 0.23 V/m (non-central residential area in Switzerland) and 1.85 V/m (university area in Australia), and across modes of public transport between 0.32 V/m (bus in rural area in Switzerland) and 0.86 V/m (Auto rickshaw in urban area in Nepal). For most outdoor areas the major exposure contribution was from mobile phone base stations. Otherwise broadcasting was dominant. Uplink from mobile phone handsets was generally very small, except in Swiss trains and some Swiss buses. This study demonstrates high RF-EMF variability between the 94 selected microenvironments from all over the world. Exposure levels tended to increase with increasing urbanity. In most microenvironments downlink from mobile phone base stations is the most relevant contributor."
"The observed average (geometric mean) magnetic field values were; bed 0.85, bedroom 1.39 mG, baby cot 0.39 mG, children’s play area 0.47 mG, and family room 0.30 mG. Our results show considerable variation in the fields to which residents are typically exposed, particularly in beds (21.83%) and bedrooms (33.33%) where the percentage of measurements greater than 4 mG was considerable. Some emissions exceeded the general public exposure levels of the ICNIRP Guidelines, with the potential for residents to be exposed above these levels. However, away from electrical appliances, the average field in all rooms was 0.30–1.39 mG. We show that simple precautions can be applied to reduce exposure to ELF-MFs in residences and thereby minimize potential risks to health and wellbeing."
"All values were far below International Commission on Non-Ionizing Radiation Protection's reference values, but most mean levels measured were above the precautionary target level of 3-6 µW/m2 as proposed by the Bioinitiative Report. The length of time wireless devices are used is an essential determinant in overall exposure. Measures to minimize children's exposure to RF radiation in school would include preferring wired connections, allowing laptops, tablets and mobile phones only in flight mode and deactivating Wi-Fi access points, when not used for learning purposes."
"Our results were below the reference level on 10,000,000 µW/m2 established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), which, however, are less credible, as they do not take non-thermal effects into consideration and are not based on sound scientific evaluation. Our highest measured mean level at Järntorget was 0.24% of the ICNIRP level. A number of studies have found adverse, non-thermal (no measurable temperature increase) health effects far below the ICNIRP guidelines."
"This paper describes measurements and computational modelling carried out in the MOBI-Kids case-control study to assess the extremely low frequency (ELF) exposure of the brain from use of mobile and cordless phones."
"Almost all of the total measured levels were above the precautionary target level of 3-6 µW/m2 as proposed by the BioInitiative Working Group in 2012. That target level was one-tenth of the scientific benchmark providing a safety margin either for children, or chronic exposure conditions. We compare the levels of RF radiation exposures identified in the present study to published scientific results reporting adverse biological effects and health harm at levels equivalent to, or below those measured in this Stockholm Central Railway Station project. It should be noted that these RF radiation levels give transient exposure, since people are generally passing through the areas tested, except for subsets of people who are there for hours each day of work."
"Measurement results showed that the maximum recorded value of total electric field strength has exceeded International Commission on Non-Ionizing Radiation Protection general public exposure reference levels at 2.5 % of locations and Serbian national reference levels at 15.6 % of locations. It should be emphasised that the values exceeding the reference levels were observed only outdoor, while in indoor total electric field strength in no case exceeded the defined reference levels."
"The relative contributions from different sources to the total exposure in terms of exposure quotient were evaluated and found to be 46% from FM radio, 26% from GSM900, 15% from DECT phones, 9% from WLAN, 3% from unknown sources, and 1% from TV broadcasting. RF sources located outdoors contribute about 73% to the population exposure indoors."
"While experimental studies employing simulated EMF-emissions present a strong inconsistency among their results with less than 50% of them reporting effects, studies employing real mobile phone exposures demonstrate an almost 100% consistency in showing adverse effects. This consistency is in agreement with studies showing association with brain tumors, symptoms of unwellness, and declines in animal populations. Average dosimetry in studies with real emissions can be reliable with increased number of field measurements, and variation in experimental outcomes due to exposure variability becomes less significant with increased number of experimental replications. We conclude that, in order for experimental findings to reflect reality, it is crucially important that exposures be performed by commercially available mobile phone handsets."
"As the stimulation results suggest, the spaces around incoming panels, transformers, and cables were recognized as hazardous zones of indoor electric substations. Considering the health effects of chronic exposure to magnetic fields, it would be possible to minimize exposure to these contaminants at workplaces by identification of risky zones and observation of protective considerations."
"Generally, results obtained were found to be below the occupational reference levels of the International Commission on Non-Ionizing Radiation Protection, but at some locations, the field intensity was 4.3 times higher than the reference levels for the general public."
"For Global System for Mobile Communications (GSM) technology at 1800 MHz, we found that by connecting to a small cell, the brain exposure of the user could realistically be reduced by a factor 35 and the whole-body exposure by a factor 11."
"The median of all-night measurements of ELF-MFs at 50 Hz decreased from 13.50 to 11.37 nT. The median of total RF-EMFs increased from 28.13 to 52.16 uW/m(2). Highest increases were found for universal mobile telecommunication system (UMTS) and wireless local area networks (WLAN)."
"Misclassification was substantial, with large random errors, small systematic errors, and no significant differences between cases and controls. The average difference between self-reported and operator start year was -0.62 (95% confidence interval: -1.42, 0.17) years for cases and -0.71 (-1.50, 0.07) years for controls, standard deviations were 3.92 and 4.17 years, respectively. Agreement between self-reported and operator-recorded data categorized into short, intermediate and long-term use was moderate (kappa statistic: 0.42). Should an association exist, dilution of risk estimates and distortion of exposure-response patterns for time since first mobile phone use could result from the large random errors in self-reported start year."
"The results show that the variation in the averaged SAR among the heads can reach up to 16.4 dB at a 1 cm(3) cube inside the brain (field-sensor method) and alternatively up to 15.8 dB in the medulla region (Talairach method). In conclusion, we show head morphology as an important uncertainty source for dosimetric studies of mobile phones. Therefore, any dosimetric analysis dealing with RF dose at a specific region in the brain (e.g., tumor risk analysis) should be based upon real morphology."
"The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm(-2) with an average value equalling 3.64 μW cm(-2). Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm(-2). The highest radiation leakage from any tested oven was ∼16.4 μW cm(-2), and found in two cases only."
"This study demonstrates that personal RF-EMF exposure is affected by one's own mobile phone in stand-by mode because of its regular location update. Further dosimetric studies should quantify the contribution of location updates to the total RF-EMF exposure in order to clarify whether the duration of mobile phone use, the most common exposure surrogate in the epidemiological RF-EMF research, is actually an adequate exposure proxy."
"RF EMF emissions measured from continuous and pulsed electrotherapeutic diathermy devices may well be higher than OELs at specific distances, i.e., at 1 m, which is currently designated to be a safe distance for physiotherapists. The minimum safe distance for physiotherapists should be revised to at least 2 m for CSWD and 1.5 m for PSWD."
"Adolescents' estimation of their cellphone use indicated that it was performed on a mental logarithmic scale. This is the first time this phenomenon has been observed in the estimation of recalled, as opposed to observed, numerical quantities. Our findings provide empirical justification for log-transforming data for analysis. We recommend the use of the geometric rather than arithmetic mean when a recalled numerical range is provided. A point of calibration may improve recall."
"On the contrary, the power supply induces strong intracorporal electric current densities in the fetus and in the adult subject, which are respectively 182-263% and 71-483% higher than ICNIRP 98 basic restriction recommended to prevent adverse health effects. Laptop is paradoxically an improper site for the use of a LTC, which consequently should be renamed to not induce customers towards an improper use."
"No difference in the medians of all-night ELF-MFs of railway current was observed. RF-EMFs increased from 41.35 to 59.56 uW m(-2). Increases primarily occurred in the frequency ranges of Global System for Mobile 900 MHz, Universal Mobile Telecommunications System and Wireless Local Area Network. Television changeover from analogue to digital resulted in a reduction within the Ultra-high Frequency-band from 0.47 to 0.35 uW m(-2). The base stations of the recently established terrestrial trunked radio system caused a median of 0.05 uW m(-2)."
"We observed generally higher RF power output in rural areas. There was good correlation between average power control settings in the software-modified phones and power measurements in the phantoms. Our findings suggest that phone technology, and to a lesser extent, degree of urbanization, are the two stronger influences on RF power output. Software-modified phones should be useful for improving epidemiologic exposure assessment."
"On measurements of 120 phones, the three-dimensional distribution of SAR in phantom models did not appear to be related to particular external phone characteristics or measurement characteristics, which could be used for refining the assessment of exposure to radiofrequency energy within the brain in epidemiological studies such as the Interphone."
"A total of 225,414 electric field strength measurements were recorded in 12 different RF bands. Summary statistics were calculated with the robust regression on order statistics method. We found evidence for statistically significant variability of individual RF exposure across days of the week, though the relative magnitude of the differences observed was small. Larger studies are needed to validate these results and determine whether day of the week is an important determinant for inclusion in individual RF exposure prediction models that remain urgently needed to conduct epidemiological studies on potential health effects."
"Highest total personal RF-EMF exposure was measured inside transport vehicles and was well below international exposure limits. This is mainly due to mobile phone handsets. Mobile telecommunication can be considered to be the main contribution to total RF-EMF exposure in all microenvironments."
"For the first time, in situ electromagnetic field exposure of the general public to fields from long term evolution (LTE) cellular base stations is assessed. Exposure contributions due to different radiofrequency (RF) sources are compared with LTE exposure at 30 locations in Stockholm, Sweden. Total exposures (0.2-2.6 V/m) satisfy the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference levels (from 28 V/m for frequency modulation (FM), up to 61 V/m for LTE) at all locations. LTE exposure levels up to 0.8 V/m were measured, and the average contribution of the LTE signal to the total RF exposure equals 4%."
"In this article, personal electromagnetic field measurements are converted into whole-body specific absorption rates for exposure of the general public. Whole-body SAR values calculated from personal exposure meter data are compared for different human spheroid phantoms: the highest SAR values (at 950 MHz) are obtained for the 1-year-old child (99th percentile of 17.9 microW/kg for electric field strength of 0.36 V/m), followed by the 5-year-old child, 10-year-old child, average woman, and average man. For the 1-year-old child, whole-body SAR values due to 9 different radiofrequency sources (FM, DAB, TETRA, TV, GSM900 DL, GSM1800 DL, DECT, UMTS DL, WiFi) are determined for 15 different scenarios. An SAR matrix for 15 different exposure scenarios and 9 sources is provided with the personal field exposure matrix. Highest 95th percentiles of the whole-body SAR are equal to 7.9 microW/kg (0.36 V/m, GSM900 DL), 5.8 microW/kg (0.26 V/m, DAB/TV), and 7.1 microW/kg (0.41 V/m, DECT) for the 1-year-old child, with a maximal total whole-body SAR of 11.5 microW/kg (0.48 V/m) due to all 9 sources. All values are below the basic restriction of 0.08 W/kg for the general public. 95th percentiles of whole-body SAR per V/m are equal to 60.1, 87.9, and 42.7 microW/kg for GSM900, DAB/TV, and DECT sources, respectively. Functions of the SAR versus measured electric fields are provided for the different phantoms and frequencies, enabling epidemiological and dosimetric studies to make an analysis in combination with both electric field and actual whole-body SAR."
"All measurements were well below International Commission on Non-Ionizing Radiation Protection (ICNIRP) guideline levels. Average night-time ELF-MFs (long-term measurement from 10 pm to 6 am, geometric mean over households) above 100 nT were obtained in 2.3%, and RF-EMFs above 1000 microW/m(2) in 7.1% of households. Highest ELF-EFs were primarily due to lamps beside the bed (max = 166 V/m), and highest ELF-MFs because of transformers of devices (max = 1030 nT) or high current of power lines (max = 380 nT). The highest values of RF-EMFs were caused by DECT telephone base stations (max = 28979 microW/m(2)) and mobile phone base stations (max = 4872 microW/m(2)). Simple reduction measures resulted in an average decrease of 23 nT for ELF-MFs, 23 V/m for ELF-EFs, and 246 microW/m(2) for RF-EMFs. A small but statistically significant correlation between ELF-MF exposure and overall RF-EMF levels of R = 0.16 (P = 0.008) was computed that was independent of type (flat, single family) and location (urban, rural) of houses."
"There was a statistically significant positive relationship (r = 0.38, p < 0.01) between cordless and mobile phone use. Taken together, this increases total RF exposure and its ratio in high-to-low mobile users. Therefore, the design and analysis of future epidemiological telecommunication studies need to assess cordless phone exposure to accurately evaluate total RF telephone exposure effects."
"The accuracy of the models is confirmed, with small relative errors: less than 5-10%. Moreover, we confirm that the greatest power is emitted when the network is saturated with traffic. Using this, we give a simple technique to quickly estimate power output based on traffic levels and give examples showing how this might be used in practice to predict current or future power output from a Wi-Fi network."
"This means that each experiment with horizontal polarization of magnetic fields has a higher probability to result in "not changed melatonin level" pattern. On the other hand, ANNs, a more powerful model which has not been introduced in predicting melatonin excretion patterns in the rat exposed to ELF-MF, showed high performance measure values and higher reliability, especially obtaining 0.55 value of MCC through jackknife tests. Obtained results showed that such predictor models are promising and may play a useful role in defining guidelines for experimental designs relating to exposure conditions. In conclusion, analysis of the bioelectromagnetic data could result in finding a relationship between electromagnetic fields and different biological processes."
"CONCLUSIONS: Although all the measure dates on the ground around the base station could be below the primary standard in "environment electromagnetic wave hygienic standard" (GB9175-88), there were still a minorities of windows which exposed to the base station were higher, and the outside or inside of a few window was even higher beyond the primary safe level defined standard. The aluminum alloys security net can partly shield the microwave radiation from the mobile phone base station."
"Most of the time, recorded field strengths were not detectable with the exposure meter. Total field, cordless phones, WiFi-microwave, and FM transmitters stood apart with a proportion above the detection threshold of 46.6%, 17.2%, 14.1%, and 11.0%, respectively. The total field mean value was 0.201V/m, higher in urban areas, during daytime, among adults, and when moving. When focusing on specific channels, the highest mean exposure resulted from FM sources (0.044V/m), followed by WiFi-microwaves (0.038V/m), cordless phones (0.037V/m), and mobile phones (UMTS: 0.036V/m, UMTS: 0.037V/m). Various factors, however, contributed to a high variability in RF exposure assessment. These population-based estimates should therefore be confirmed by further surveys to better characterize the exposure situation in different microenvironments."
"Wireless networking is being increasingly used in schools and it is important to quantify the exposure of children to the radiofrequency fields. This paper presents a series of laboratory measurements with selected items of Wi-Fi equipment known to be popular in UK schools. Unlike most of the previous similar studies, a signal analyzer has been used in this work with a bandwidth of 25 MHz allowing the detection of the whole WLAN signal. The results revealed the effect of having multiple transmitting antennas, as currently used in most of the wireless enabled laptops."
"Extremely low frequency (ELF) magnetic fields in cell culture incubators have been measured. Values of the order of tens of muT were found which is in sharp contrast to the values found in our normal environment (0.05-0.1muT). There are numerous examples of biological effects found after exposure to MF at these levels, such as changes in gene expression, blocked cell differentiation, inhibition of the effect of tamoxifen, effects on chick embryo development, etc. We therefore recommend that people working with cell culture incubators check for the background magnetic field and take this into account in performing their experiments, since this could be an unrecognised factor of importance contributing to the variability in the results from work with cell cultures."
"Despite numerous limiting factors entailing a high variability in RF exposure assessment, but owing to a sound statistical technique, we found that exposures from GSM and DCS base stations increase with distance in the near source zone, to a maximum where the main beam intersects the ground. We believe these results will contribute to the on-going public debate over the siting of base stations and their associated emissions."
"Our findings suggest that the reference levels of current electromagnetic (EM) safety guidelines for demonstrating compliance as well as some of the current measurement standards are not consistent with the basic restrictions and need to be revised."
"In this study, the aim was to evaluate the level of RF electromagnetic radiation in Yenimahalle Sentepe Dededoruk Hill in Ankara, Turkey that is a multiple-transmitter site hosting 64 different TV and radio towers and one base station for mobile phone communication. The site has been of interest as it is nearby a residential community. Within the technical input data available on 31 of the radio and TV transmitters, the calculated radiation level in this particular region was found to be approximately four times higher than the permitted standards of Turkey, which are the same as the ICNIRP standards. Electromagnetic field measurement is needed in the site."
"Exposure to 50 Hz magnetic field (MF) was evaluated in 31 multi-level apartment buildings with built-in step-down transformer stations. In each building, three apartments were selected: one apartment located immediately above the transformer room (index apartment), one located on the same floor and one on a higher floor. The mean value of measured MFs was 0.98 microT in apartments above transformers, 0.13 microT on the same floor, and 0.1 microT in on higher floors. The mean measured MF value was higher than 0.2 microT in 30 (97%) index apartments, 4 (14%) on the same floor as the index apartments and 4 (13%) on higher floors. The corresponding numbers were 25 (81%), 0 and 0, respectively, when 0.4 microT was used as cut-point. It is concluded that apartments in building with built-in transformers can be reliably classified into high and low-exposure categories based on their location in relation to transformers."
"The average relative SAR is highest in the temporal lobe (6-15%, depending on frequency, of the spatial peak SAR in the most exposed region of the brain) and the cerebellum (2-10%) and decreases very rapidly with increasing depth, particularly at higher frequencies. The SAR distribution appears to be fairly similar across phone models, between older and newer phones and between phones with different antenna types and positions. Analyses of risk by location of tumour are therefore important for the interpretation of results of studies of brain tumours in relation to mobile phone use."
"The corresponding numbers for the 0.4 microT cut-off point were 19 (63%), 4 (14%), and 1 (3.3%). The higher MF level in the FF reference apartments indicates that they should not be considered "unexposed" in epidemiological studies. If such apartments are excluded, a transformer station under the floor predicts 24-h apartment mean MF with a sensitivity of 0.41 (or 0.58) and a specificity of 0.997 (or 0.97), depending on the MF cut-off point (0.2 or 0.4 microT). The results indicate that apartments can be reliably classified as high and low MF field categories based on the known location of transformer stations."
"Since operation in the near-field of these devices cannot be excluded, dosimetric evaluation is the most straightforward technique for testing compliance when low-power exclusions are not applicable. The suitability of the suggested methods is demonstrated through the examination of five classes of short-range transmitters."
"The exposure to the user, particularly if the antenna of the client card were placed against his or her body, would require different measurement techniques beyond the scope of this study. In all cases, the measured Wi-Fi signal levels were very far below international exposure limits (IEEE C95.1-2005 and ICNIRP) and in nearly all cases far below other RF signals in the same environments. An discusses technical aspects of the IEEE 802.11 standard on which WLANs operate that are relevant to determining the levels of RF energy exposure from WLANs. Important limiting factors are the low operating power of client cards and access points, and the low duty cycle of transmission that normally characterizes their operation."
"In this paper, we confirm the significance of microwave reflection reported in our previous Letter by experimental and numerical studies. Furthermore, we show that "hot spots" often emerge in reflective areas, where the local exposure level is much higher than average. Such places include elevators, and we discuss other possible environments including trains, buses, cars, and airplanes."
"This paper compares a number of typical exposures to wireless devices, such as mobile phones, DECT phones, wireless access points, wireless laptop and bluetooth devices, and wireless baby monitors. It confirms that typical exposures to mobile phone base stations are very similar to typical exposures whilst using a wirelessly networked laptop."
"Magnetic field strengths were low, with average (RMS) values of 0.03 +/- 0.02 microT across all residences. In contrast, background field ellipticities were high, on average 47 +/- 11%. Microwave and electric ovens produced the highest ellipticities: mean respective values of 21 +/- 21% and 21 +/- 17% were observed 20 cm away from these appliances. There was a negative correlation between field strength and field polarization, which we attribute to the higher relative field contribution close to each individual (single-phase) appliance. The measurements demonstrate that domestic magnetic fields are extremely complex and cannot simply be characterized by traditional measurements such as time-weighted average or peak exposure levels. We conclude that ellipticity should become a relevant metric for future epidemiological studies of health and ELF-MF exposure."
"This correlation, combined with both frequent exposure opportunity for bathing children and substantial dose to bone marrow resulting from contact, lead us to suggest that contact current due to V(W-E) could explain the association between high residential magnetic fields and childhood leukemia."
"These results can be analysed in terms of the charge density present. This analysis suggests that typically 2000 excess negative charges per cm3 are required to match the measured DC fields. Such space charge will result in unipolar aerosol charging in excess of the normal bipolar steady state charge distribution of pollutant aerosols. This may lead to increased lung deposition on inhalation."
"The observations demonstrate a mode of increased exposure to pollutant aerosols under high voltage power lines by increased deposition on the body. The total (indoor + outdoor) 218Po and 214Po dose to the basal layer of facial skin is estimated to be increased by between 1.2 and 2.0 for 10% of time spent outdoors under high voltage power lines."